Nortel-MsCarrier-MscPassport-VcTesterMIB :: mscVctDnaOutDefaultPathSensitivity

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctDnaOutDefaultPathSensitivity

mscVctDnaOutDefaultPathSensitivity

Module: Nortel-MsCarrier-MscPassport-VcTesterMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaOutDefaultPathSensitivity

OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.2.11.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the default class of path sensitivity to network for all outgoing calls using this particular Dna. The chosen default class of path sensitivity applies to all outgoing calls established using this Dna.

This attribute, if set to a value of throughput, indicates that the default class is throughput sensitive. If set to a value of delay, then the default class is delay sensitive. The default of outDefaultPathSensitivity is throughput.

This attribute is obsoleted. Please refer to defaultTransferPriority for the corresponding new attribute.

The migration function here will provide

What is mscVctDnaOutDefaultPathSensitivity?

An obsolete attribute that used to set the default outgoing path sensitivity class (throughput or delay); it has been superseded by mscVctDnaDefaultTransferPriority and is kept only for migration compatibility.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.2.11.1.11
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaOutDefaultPathSensitivity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.2.11.1.11.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaOutDefaultPathSensitivity.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.5130.2.11.1.11.1 i <value>

Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaOutDefaultPathSensitivity OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.5130mscVctNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2mscVctDnaNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.11mscVctDnaOutgoingOptionsTableNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.11.1mscVctDnaOutgoingOptionsEntryNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.11.1.11mscVctDnaOutDefaultPathSensitivityNortel-MsCarrier-MscPassport-VcTesterMIB