Nortel-MsCarrier-MscPassport-VcTesterMIB :: mscVctDnaCugPrivileged

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctDnaCugPrivileged

mscVctDnaCugPrivileged

Module: Nortel-MsCarrier-MscPassport-VcTesterMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaCugPrivileged

OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute, if set to yes indicates that this Cug is a privileged Cug. In DPN, at least one side of a call setup within a Cug must have the Cug as a privileged Cug. If set to no, then the Cug is not privileged. If both the local DTE and the remote DTE subscribe to the Cug, but it is not privileged, then the call will be cleared. This attribute is typically used for a host DTE which must accept calls from many other DTE's in which case the other DTE's cannot call one another, but can call the host. In this example, the host would have the privileged Cug, and the other DTE's would belong to the same Cug, but it would not be privileged.

What is mscVctDnaCugPrivileged?

When set to yes (the default), marks this Cug as privileged, meaning at least one side of a call within the group has this flag; this is the typical setup for a host DTE that must accept calls from many peer DTEs which cannot call each other directly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1.7
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaCugPrivileged

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1.7.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaCugPrivileged.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1.7.1 i <value>

Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDnaCugPrivileged OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.5130mscVctNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2mscVctDnaNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.2mscVctDnaCugNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.2.10mscVctDnaCugCugOptionsTableNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1mscVctDnaCugCugOptionsEntryNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.2.2.10.1.7mscVctDnaCugPrivilegedNortel-MsCarrier-MscPassport-VcTesterMIB