Nortel-MsCarrier-MscPassport-VcTesterMIB :: mscVctDcDataPath

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-VcTesterMIB › mscVctDcDataPath

mscVctDcDataPath

Module: Nortel-MsCarrier-MscPassport-VcTesterMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDcDataPath

OID (numeric): 1.3.6.1.4.1.562.36.2.1.5130.3.10.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the data path to be used by Virtual Circuits on this interface. The value of the dataPath attribute in the Dna component is overridden by this attribute if the value is not useDnaValue.

This value applies to the connection after data transfer state is reached. All the data and control trafic will be sent using this data path. If the provisioned dataPath is not available the connection is not established.

The value of the dataPath is signalled by both ends of the connection. If this value is not the same at both ends dprsOnly is used for the duration of the connection.

A virtual circuit connection is always established using dprsOnly even if this attribute is provisioned as some other value.

dprsOnly - dynamic packet routing system is used

dprsMcsOnly - dprs Multi-Service Cut-Through Switching path is used.

dprsMcsFirst - dprs Multi-Service Cut-Through Switching path is used if it is available. If it is not avaliable dprsOnly is used.

useDnaValue - use the value provisioned in Dna component.

What is mscVctDcDataPath?

Selects the data path for virtual circuits on this direct call: dprsOnly, dprsMcsOnly, dprsMcsFirst, or useDnaValue (default), which defers to the owning Dna's dataPath setting instead of specifying one here.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.3.10.1.11
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDcDataPath

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.5130.3.10.1.11.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDcDataPath.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.5130.3.10.1.11.1 i <value>

Start monitoring Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-VcTesterMIB::mscVctDcDataPath OID value, configure state conditions and alerts, and monitor any Nortel Networks Magellan Passport switch (X.25/PVC virtual-circuit tester) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.5130mscVctNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.3mscVctDcNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.3.10mscVctDcOptionsTableNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.3.10.1mscVctDcOptionsEntryNortel-MsCarrier-MscPassport-VcTesterMIB
1.3.6.1.4.1.562.36.2.1.5130.3.10.1.11mscVctDcDataPathNortel-MsCarrier-MscPassport-VcTesterMIB