Description: This attribute defines the type of CRC used.
The CRC value calculated is appended to the end of the frames transmitted to the link. The CRC value is removed from the end of frames received from the link and checked for correctness. NoCrc means that CRC is not used.
What is mscDpnGateUtpFramerFrameCrcType?
This read-write value sets the CRC type appended to transmitted frames and checked on received frames for this Framer: crc16(0) (default), crc32(1), or noCrc(2) to disable CRC checking. Admins must match this to what the far-end equipment expects for frames to be validated correctly.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.3 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerFrameCrcType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.3.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerFrameCrcType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.3.1 i <value>
Start monitoring Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerFrameCrcType OID value, configure state conditions and alerts, and monitor any Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.61 | mscDpnGate | Nortel-MsCarrier-MscPassport-DpnTrunksMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.61.2 | mscDpnGateUtp | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2 | mscDpnGateUtpFramer | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.11 | mscDpnGateUtpFramerLinkTable | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1 | mscDpnGateUtpFramerLinkEntry | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |
| 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.3 | mscDpnGateUtpFramerFrameCrcType | Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB |