Module: Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerDataInversion

OID (numeric): 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute determines whether data bits are to be inverted (1 to 0 and 0 to 1) before transmission of frames to the interface. If the value of this attribute is On, the incoming data bits will also be inverted when frames are received from the link before being processed.

This option is typically used in hdlc framing mode when inversion is used to guarantee 1's density.

Note that aborts (in hdlc and interrupting modes) are corrupted when data is inverted.

What is mscDpnGateUtpFramerDataInversion?

This read-write value turns data-bit inversion off(0) (default) or on(16) for frames sent and received on this Framer's link, typically used in HDLC mode to guarantee ones-density; note that turning it on corrupts abort sequences. Admins enable this only when the connected equipment or line encoding scheme specifically requires bit-inversion.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.2
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerDataInversion

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.2.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerDataInversion.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.2.1 i <value>

Start monitoring Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-UtpDpnTrunksMIB::mscDpnGateUtpFramerDataInversion OID value, configure state conditions and alerts, and monitor any Nortel/Alcatel-Lucent Passport packet switch (UTP-based DPN trunk) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.61mscDpnGateNortel-MsCarrier-MscPassport-DpnTrunksMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.61.2mscDpnGateUtpNortel-MsCarrier-MscPassport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.2.2mscDpnGateUtpFramerNortel-MsCarrier-MscPassport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.2.2.11mscDpnGateUtpFramerLinkTableNortel-MsCarrier-MscPassport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.2.2.11.1mscDpnGateUtpFramerLinkEntryNortel-MsCarrier-MscPassport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.2.2.11.1.2mscDpnGateUtpFramerDataInversionNortel-MsCarrier-MscPassport-UtpDpnTrunksMIB