Nortel-MsCarrier-MscPassport-PorsTrunksMIB :: mscTrkPaMaxReservedBwOut

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-PorsTrunksMIB › mscTrkPaMaxReservedBwOut

mscTrkPaMaxReservedBwOut

Module: Nortel-MsCarrier-MscPassport-PorsTrunksMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-PorsTrunksMIB::mscTrkPaMaxReservedBwOut

OID (numeric): 1.3.6.1.4.1.562.36.2.1.60.4.10.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute controls the percentage of trunk bandwidth which may be reserved by outgoing path oriented traffic on the trunk. The sum of requiredBandwidth attributes for all paths on this trunk must not exceed this attribute. Setting this attribute to zero (0) prevents paths from being established on this trunk. The limit of reserved bandwidth for incoming path oriented traffic is set using the same attribute on the trunk component on the other end of the trunk. If this attribute is set to 100% connectionless traffic is given a minimum of 1Kbit per second for administrative traffic. This attribute may now be changed without the trunk being restaging. If the value is decreased calls may be bumped as necessary to free up bandwdith. Increasing the value will have no impact on existing calls and new calls will be able to use the new bandwidth.

What is mscTrkPaMaxReservedBwOut?

Read-write percentage (0-100, default 50) of this trunk's outgoing bandwidth that path-oriented traffic may reserve in total; setting it to 0 blocks new paths from being established on the trunk, while raising or lowering it can be done live without restaging.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.60.4.10.1.2
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-PorsTrunksMIB::mscTrkPaMaxReservedBwOut

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.60.4.10.1.2.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-PorsTrunksMIB::mscTrkPaMaxReservedBwOut.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.60.4.10.1.2.1 i <value>

Start monitoring Nortel MsCarrier MscPassport WAN switch (Packet-over-Ring Service trunks) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-PorsTrunksMIB::mscTrkPaMaxReservedBwOut OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport WAN switch (Packet-over-Ring Service trunks) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.60mscTrkNortel-MsCarrier-MscPassport-TrunksMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.60.4mscTrkPaNortel-MsCarrier-MscPassport-PorsTrunksMIB
1.3.6.1.4.1.562.36.2.1.60.4.10mscTrkPaProvTableNortel-MsCarrier-MscPassport-PorsTrunksMIB
1.3.6.1.4.1.562.36.2.1.60.4.10.1mscTrkPaProvEntryNortel-MsCarrier-MscPassport-PorsTrunksMIB
1.3.6.1.4.1.562.36.2.1.60.4.10.1.2mscTrkPaMaxReservedBwOutNortel-MsCarrier-MscPassport-PorsTrunksMIB