All MIBs › Nortel-MsCarrier-MscPassport-HdlcTransparentMIB › mscHtdsPlcPathFailureAction
mscHtdsPlcPathFailureAction
Module: Nortel-MsCarrier-MscPassport-HdlcTransparentMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-HdlcTransparentMIB::mscHtdsPlcPathFailureAction
OID (numeric): 1.3.6.1.4.1.562.36.2.1.82.3.10.1.17
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute is used to specify whether the application can tolerate momentary interruption of a path while a new path is selected. If disconnectConnection is chosen, the application is informed as soon as possible about a failure by disconnection. If the attribute is set to reRoutePath, the path may attempt an immediate reroute, provided the failure is a recoverable failure. If rerouting fails the application is informed of the failure. With this option set to reRoutePath the LCo may wait up to 30 seconds before informing the service of complete disconnection in order to allow both ends to attempt to reconnect. Note that if PLC components are different at both ends only the calling end is allowed to reconnect. All pathTypes respect this attribute. Also on a manualPath with both ends provisioned with independent paths (at least with respect to the failure) this option will have the desired effect that the path is rerouted without complete disconnection at both ends.
What is mscHtdsPlcPathFailureAction?
Controls how this path handles a momentary interruption: disconnectConnection(0, tell the application about the failure immediately) or reRoutePath(1, the default, try an immediate reroute first, giving both ends up to 30 seconds to reconnect before declaring the connection down). An admin sets this to disconnectConnection when the application above this path can't tolerate any silent gap during a reroute attempt.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.82.3.10.1.17 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-HdlcTransparentMIB::mscHtdsPlcPathFailureAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.82.3.10.1.17.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-HdlcTransparentMIB::mscHtdsPlcPathFailureAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.82.3.10.1.17.1 i <value>
Start monitoring Nortel MsCarrier Passport switch (HDLC-transparent circuit emulation) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-HdlcTransparentMIB::mscHtdsPlcPathFailureAction OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switch (HDLC-transparent circuit emulation) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.82 | mscHtds | Nortel-MsCarrier-MscPassport-HdlcTransparentMIB |
| 1.3.6.1.4.1.562.36.2.1.82.3 | mscHtdsPlc | Nortel-MsCarrier-MscPassport-HdlcTransparentMIB |
| 1.3.6.1.4.1.562.36.2.1.82.3.10 | mscHtdsPlcProvTable | Nortel-MsCarrier-MscPassport-HdlcTransparentMIB |
| 1.3.6.1.4.1.562.36.2.1.82.3.10.1 | mscHtdsPlcProvEntry | Nortel-MsCarrier-MscPassport-HdlcTransparentMIB |
| 1.3.6.1.4.1.562.36.2.1.82.3.10.1.17 | mscHtdsPlcPathFailureAction | Nortel-MsCarrier-MscPassport-HdlcTransparentMIB |