All MIBs › Nortel-MsCarrier-MscPassport-Frf5EpMIB › mscMcsMgrFrf5EpGEpLmiProcedures
mscMcsMgrFrf5EpGEpLmiProcedures
Module: Nortel-MsCarrier-MscPassport-Frf5EpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpLmiProcedures
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute selects the procedures to be used for the Local Management Interface. The following are the supported procedures:
none: no Local Management Interface procedures are running on the ATM VCC. This accomodates remote interworking functions which do not implement LMI procedures. In this case, the remaining attributes of this group will be ignored.
ccitt: Local Management Interface procedures from the CCITT specification are supported. Dlci/0 is used for the LMI protocol, to comply with FRF.5.
ansi: Local Management Interface procedures from the ANSI specification are supported. DLCI 0 is used for the LMI protocol.
What is mscMcsMgrFrf5EpGEpLmiProcedures?
Which Local Management Interface procedure this end point runs: none (no LMI at all, for remote ends that don't implement it), ccitt (CCITT/ITU-T LMI on DLCI 0, the default, required by FRF.5), or ansi (ANSI LMI, also on DLCI 0); an admin sets this to match what the remote Frame Relay/ATM interworking device expects.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpLmiProcedures
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpLmiProcedures.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1.1.1 i <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpLmiProcedures OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.14 | mscMcsMgrFrf5EpG | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3 | mscMcsMgrFrf5EpGEp | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.2 | mscMcsMgrFrf5EpGEpLmi | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10 | mscMcsMgrFrf5EpGEpLmiParmsTable | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1 | mscMcsMgrFrf5EpGEpLmiParmsEntry | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.2.10.1.1 | mscMcsMgrFrf5EpGEpLmiProcedures | Nortel-MsCarrier-MscPassport-Frf5EpMIB |