Nortel-MsCarrier-MscPassport-Frf5EpMIB :: mscMcsMgrFrf5EpGEpEpdExcessInformationRate

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-Frf5EpMIB › mscMcsMgrFrf5EpGEpEpdExcessInformationRate

mscMcsMgrFrf5EpGEpEpdExcessInformationRate

Module: Nortel-MsCarrier-MscPassport-Frf5EpMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdExcessInformationRate

OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.6

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the excess information rate (EIR), and represents the rate at which the network FRF.5 ATM VCC attempts to transfer information. A conservative EIR value would be the sum of the EIRs of all the individual FrAtm Dlcis multiplexed by the VCC. The eir is converted into ATM service parameters according to the conversion policy specified by the connectionTransferPriority attribute. The conversion policy is defined under the ModuleData FrameRelayService AtmNetworking TransferPriority/n component.

What is mscMcsMgrFrf5EpGEpEpdExcessInformationRate?

The provisioned Excess Information Rate (EIR, default 0 bps) for this end point, ideally set to the sum of the EIRs of the Frame Relay DLCIs it multiplexes; like the CIR, it's converted into ATM cell-rate parameters using the configured conversion policy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.6
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdExcessInformationRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.6.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdExcessInformationRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.6.1 i <value>

Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdExcessInformationRate OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.122mscMcsMgrNortel-MsCarrier-MscPassport-McsMgrMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.122.14mscMcsMgrFrf5EpGNortel-MsCarrier-MscPassport-Frf5EpMIB
1.3.6.1.4.1.562.36.2.1.122.14.3mscMcsMgrFrf5EpGEpNortel-MsCarrier-MscPassport-Frf5EpMIB
1.3.6.1.4.1.562.36.2.1.122.14.3.3mscMcsMgrFrf5EpGEpEpdNortel-MsCarrier-MscPassport-Frf5EpMIB
1.3.6.1.4.1.562.36.2.1.122.14.3.3.10mscMcsMgrFrf5EpGEpEpdProvTableNortel-MsCarrier-MscPassport-Frf5EpMIB
1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1mscMcsMgrFrf5EpGEpEpdProvEntryNortel-MsCarrier-MscPassport-Frf5EpMIB
1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.6mscMcsMgrFrf5EpGEpEpdExcessInformationRateNortel-MsCarrier-MscPassport-Frf5EpMIB