All MIBs › Nortel-MsCarrier-MscPassport-Frf5EpMIB › mscMcsMgrFrf5EpGEpEpdCommittedInformationRate
mscMcsMgrFrf5EpGEpEpdCommittedInformationRate
Module: Nortel-MsCarrier-MscPassport-Frf5EpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdCommittedInformationRate
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.5
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: This attribute specifies the committed information rate (CIR), and represents the rate at which the network FRF.5 ATM VCC agrees to transfer information under normal conditions. A conservative CIR value would be the sum of the CIRs of all the individual FrAtm Dlcis multiplexed by the VCC. The cir is converted into ATM service parameters according to the conversion policy specified by the connectionTransferPriority attribute. The conversion policy is defined under the ModuleData FrameRelayService AtmNetworking TransferPriority/n component.
What is mscMcsMgrFrf5EpGEpEpdCommittedInformationRate?
The provisioned Committed Information Rate (CIR, default 64000 bps) for this end point's Frame Relay-over-ATM connection, ideally set to the sum of the CIRs of all Frame Relay DLCIs multiplexed onto the VCC; it's converted into the actual ATM cell rates according to the configured conversion policy.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.5 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdCommittedInformationRate
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.5.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdCommittedInformationRate.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.5.1 i <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpEpdCommittedInformationRate OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.14 | mscMcsMgrFrf5EpG | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3 | mscMcsMgrFrf5EpGEp | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.3 | mscMcsMgrFrf5EpGEpEpd | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10 | mscMcsMgrFrf5EpGEpEpdProvTable | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1 | mscMcsMgrFrf5EpGEpEpdProvEntry | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.3.10.1.5 | mscMcsMgrFrf5EpGEpEpdCommittedInformationRate | Nortel-MsCarrier-MscPassport-Frf5EpMIB |