All MIBs › Nortel-MsCarrier-MscPassport-Frf5EpMIB › mscMcsMgrFrf5EpGEpDlciABitReasonToIf
mscMcsMgrFrf5EpGEpDlciABitReasonToIf
Module: Nortel-MsCarrier-MscPassport-Frf5EpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpDlciABitReasonToIf
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This attribute indicates the reason for the latest inactive A-bit status sent to the ATM VCC. The value is notApplicable when the aBitStatusToNetwork is active. The value is remoteUserSignaled if the FrAtm originating the A-Bit status has detected that the virtual circuit is down at the remote network through the LMI protocol. The FrAtm must be running network site LMI protocol for this A-Bit status reason to be sent. The value is localLmiError if the LMI protocol is down at this Ep. The value is remoteLmiError if the LMI protocol is down at the FrAtm originating this A-Bit status reason. The value is localLinkDown if the physical interface is disabled at this Ep. The value is pvcDown if no A-Bit status has been sent to this Ep (i.e., no A-Bit status has been relayed from the FrAtm). The value is remoteLinkDown if the physical interface is disabled at the FrAtm originating this A-Bit status reason.
What is mscMcsMgrFrf5EpGEpDlciABitReasonToIf?
The reason for the most recent inactive A-bit status sent toward the ATM VCC for this DLCI: notApplicable (status is active), remoteUserSignaled (the far Frame Relay side reported the circuit down via LMI), localLmiError/remoteLmiError (LMI itself is down locally or remotely), localLinkDown/remoteLinkDown (the physical interface is disabled at one end), or pvcDown (no A-bit status has ever been relayed); an admin uses this to pinpoint exactly where in the path a Frame Relay PVC broke.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10.1.2 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpDlciABitReasonToIf
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10.1.2.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpDlciABitReasonToIf.1
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGEpDlciABitReasonToIf OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.14 | mscMcsMgrFrf5EpG | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3 | mscMcsMgrFrf5EpGEp | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.4 | mscMcsMgrFrf5EpGEpDlci | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10 | mscMcsMgrFrf5EpGEpDlciOperTable | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10.1 | mscMcsMgrFrf5EpGEpDlciOperEntry | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.3.4.10.1.2 | mscMcsMgrFrf5EpGEpDlciABitReasonToIf | Nortel-MsCarrier-MscPassport-Frf5EpMIB |