All MIBs › Nortel-MsCarrier-MscPassport-Frf5EpMIB › mscMcsMgrFrf5EpGAddrRemoteAddress
mscMcsMgrFrf5EpGAddrRemoteAddress
Module: Nortel-MsCarrier-MscPassport-Frf5EpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGAddrRemoteAddress
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1.1
Node type: OBJECT-TYPE
Type: AsciiString
Access: read-write
Description: This attribute specifies the ATM End System Address (AESA) in the ISO NSAP format that is used by each EndPoint under this Frf5EpG to establish a VCC. For example, NSAP ATM address '45000006138292323F000000000020480D002900'.
What is mscMcsMgrFrf5EpGAddrRemoteAddress?
The ATM End System Address (AESA), in ISO NSAP format (e.g. '45000006138292323F000000000020480D002900'), that each End Point under this group uses to establish its ATM VCC; an admin sets this to the remote switch/endpoint's NSAP address when provisioning the FRF.5 connection.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGAddrRemoteAddress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGAddrRemoteAddress.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1.1.1 s <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-Frf5EpMIB::mscMcsMgrFrf5EpGAddrRemoteAddress OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.14 | mscMcsMgrFrf5EpG | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.2 | mscMcsMgrFrf5EpGAddr | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.2.10 | mscMcsMgrFrf5EpGAddrProvTable | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1 | mscMcsMgrFrf5EpGAddrProvEntry | Nortel-MsCarrier-MscPassport-Frf5EpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.14.2.10.1.1 | mscMcsMgrFrf5EpGAddrRemoteAddress | Nortel-MsCarrier-MscPassport-Frf5EpMIB |