Nortel-MsCarrier-MscPassport-FrameRelayUniMIB :: mscFrUniSigMaximumAggregateSvcCirHighQ

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayUniMIB › mscFrUniSigMaximumAggregateSvcCirHighQ

mscFrUniSigMaximumAggregateSvcCirHighQ

Module: Nortel-MsCarrier-MscPassport-FrameRelayUniMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigMaximumAggregateSvcCirHighQ

OID (numeric): 1.3.6.1.4.1.562.36.2.1.71.6.12.1.12

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute specifies the maximum aggregate user to network direction CIR allowed for SVCs on the interface. It is provisioned as a percentage of the link access speed. This attribute is used to limit, at this interface, the amount of guaranteed SVC throughput allowed into the network through the high priority queue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.6.12.1.12
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigMaximumAggregateSvcCirHighQ

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.6.12.1.12.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigMaximumAggregateSvcCirHighQ.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.71.6.12.1.12.1 i <value>

Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigMaximumAggregateSvcCirHighQ OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.71mscFrUniNortel-MsCarrier-MscPassport-FrameRelayUniMIB
1.3.6.1.4.1.562.36.2.1.71.6mscFrUniSigNortel-MsCarrier-MscPassport-FrameRelayUniMIB
1.3.6.1.4.1.562.36.2.1.71.6.12mscFrUniSigServParmsTableNortel-MsCarrier-MscPassport-FrameRelayUniMIB
1.3.6.1.4.1.562.36.2.1.71.6.12.1mscFrUniSigServParmsEntryNortel-MsCarrier-MscPassport-FrameRelayUniMIB
1.3.6.1.4.1.562.36.2.1.71.6.12.1.12mscFrUniSigMaximumAggregateSvcCirHighQNortel-MsCarrier-MscPassport-FrameRelayUniMIB