All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayUniMIB › mscFrUniSigCurrentAggregateSvcCirHighQ
mscFrUniSigCurrentAggregateSvcCirHighQ
Module: Nortel-MsCarrier-MscPassport-FrameRelayUniMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigCurrentAggregateSvcCirHighQ
OID (numeric): 1.3.6.1.4.1.562.36.2.1.71.6.16.1.18
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: This attribute shows the aggregate SVC CIR (for traffic transiting in the network through high priority queue) assigned to existing SVCs on the interface.
The value of currentAggregateSvcCirHighQ could be greater than the provisionable value of maximumAggregateSvcCirHighQ if the value of maximumAggregateSvcCirHighQ has been changed during the service of this FrUni.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.6.16.1.18 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigCurrentAggregateSvcCirHighQ
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.6.16.1.18.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigCurrentAggregateSvcCirHighQ.1
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniSigCurrentAggregateSvcCirHighQ OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.71 | mscFrUni | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.6 | mscFrUniSig | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.6.16 | mscFrUniSigStatsTable | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.6.16.1 | mscFrUniSigStatsEntry | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.6.16.1.18 | mscFrUniSigCurrentAggregateSvcCirHighQ | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |