All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayUniMIB › mscFrUniLmiPvcConfigParmsInFsr
mscFrUniLmiPvcConfigParmsInFsr
Module: Nortel-MsCarrier-MscPassport-FrameRelayUniMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniLmiPvcConfigParmsInFsr
OID (numeric): 1.3.6.1.4.1.562.36.2.1.71.4.10.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: When this attribute is set to yes, additional Q.933 information elements are included in the LMI Full Status message to facilitate CPE PVC parameter configuring.
When set to yes, the Check Prov command fails if the Lmi side is not set to network.
When set to yes, Check Prov fails if the number of DLCIs on the FrUni is greater than 300.
If the service is not a FrUni this attribute is ignored.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.4.10.1.9 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniLmiPvcConfigParmsInFsr
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.4.10.1.9.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniLmiPvcConfigParmsInFsr.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.71.4.10.1.9.1 i <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniLmiPvcConfigParmsInFsr OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.71 | mscFrUni | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.4 | mscFrUniLmi | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.4.10 | mscFrUniLmiParmsTable | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.4.10.1 | mscFrUniLmiParmsEntry | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.4.10.1.9 | mscFrUniLmiPvcConfigParmsInFsr | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |