All MIBs › Nortel-MsCarrier-MscPassport-FrameRelayUniMIB › mscFrUniDlciSpUpdateBCI
mscFrUniDlciSpUpdateBCI
Module: Nortel-MsCarrier-MscPassport-FrameRelayUniMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniDlciSpUpdateBCI
OID (numeric): 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies whether internal Backward Congestion Indication (BCI) bits will report congestion external to the Passport network, as communicated through incoming BECN bits.
If updateBCI is set to on, then BCI bits for incoming frames will be set if the BECN on the frame is set. If updatBCI is set to off, then incoming BECN bits will have no effect.
Setting updateBCI on for a DLCI means that the remote end of the DLCI, which is specified by the remotedna and remotedlci attributes of the dc component of the dlci, may perform Rate Adaptation using the flow of incoming BECN bits, in addition to internal Passport congestion management systems.
If the rateAdaptation attribute of the remote dlci is provisioned as eirOnly, cirProportionate, or on, then congestion from another network connected to a Passport network may trigger dynamic congestion management. If the rateAdaptation attribute of the remote dlci is provisioned to off, then the setting of updateBCI attribute here will have no effect..
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1.10 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniDlciSpUpdateBCI
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1.10.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniDlciSpUpdateBCI.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1.10.1 i <value>
Start monitoring Nortel MsCarrier Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FrameRelayUniMIB::mscFrUniDlciSpUpdateBCI OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.71 | mscFrUni | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.5 | mscFrUniDlci | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.5.4 | mscFrUniDlciSp | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.5.4.11 | mscFrUniDlciSpParmsTable | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1 | mscFrUniDlciSpParmsEntry | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |
| 1.3.6.1.4.1.562.36.2.1.71.5.4.11.1.10 | mscFrUniDlciSpUpdateBCI | Nortel-MsCarrier-MscPassport-FrameRelayUniMIB |