mscDpnGateFrAccessReceiveErrorSensitivity

Module: Nortel-MsCarrier-MscPassport-FraDpnTrunksMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-FraDpnTrunksMIB::mscDpnGateFrAccessReceiveErrorSensitivity

OID (numeric): 1.3.6.1.4.1.562.36.2.1.61.4.10.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: This attribute is the allowable error rate beyond which the Unacknowledged, Utp, or FrAccess component can be degraded if it persists for a duration longer than the maximumErrorInterval. The threshold is expressed as a percentage of number of errored frames in the last interval per number of frames received in the last interval. The exception to this is a value of zero, which indicates that the mechanism is completely disabled. The configurable values are: 0 = the mechanism is completely disabled 1 = 1/(2**1) 2 = 1/(2**2) 3 = 1/(2**3) : 10 = 1/(2**10)

What is mscDpnGateFrAccessReceiveErrorSensitivity?

The allowable frame error rate (0-10, default 3) beyond which the link can be degraded if sustained past mscDpnGateFrAccessMaximumErroredInterval, expressed as a negative power of two (e.g. 3 means roughly 1 error per 8 frames); a value of 0 disables the mechanism entirely.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.4.10.1.2
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-FraDpnTrunksMIB::mscDpnGateFrAccessReceiveErrorSensitivity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.61.4.10.1.2.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-FraDpnTrunksMIB::mscDpnGateFrAccessReceiveErrorSensitivity.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.61.4.10.1.2.1 i <value>

Start monitoring Nortel MsCarrier MscPassport switch (Frame Relay Adaptation DPN trunks) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-FraDpnTrunksMIB::mscDpnGateFrAccessReceiveErrorSensitivity OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (Frame Relay Adaptation DPN trunks) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.61mscDpnGateNortel-MsCarrier-MscPassport-DpnTrunksMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.61.4mscDpnGateFrAccessNortel-MsCarrier-MscPassport-FraDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.4.10mscDpnGateFrAccessProvTableNortel-MsCarrier-MscPassport-FraDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.4.10.1mscDpnGateFrAccessProvEntryNortel-MsCarrier-MscPassport-FraDpnTrunksMIB
1.3.6.1.4.1.562.36.2.1.61.4.10.1.2mscDpnGateFrAccessReceiveErrorSensitivityNortel-MsCarrier-MscPassport-FraDpnTrunksMIB