Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB :: mscLpEE1LosAlarm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB › mscLpEE1LosAlarm

mscLpEE1LosAlarm

Module: Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB

OID (symbolic): Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB::mscLpEE1LosAlarm

OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.29.16.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This attribute indicates whether a LOS (Loss of Signal) alarm state has been entered. A LOS alarm is declared after LOS defects have been observed and accumulated for a period of 2 seconds +/- 0.5 second . A LOS defect is detected upon observing all zeros for 150 ms . If the LOS defects are intermittently occurring, the LOS defect accumulator is decremented at a rate of 1/10 of the incrementing rate (alarm integration ratio of 1/10), with all measurements based on a 200 ms polling cycle. The port goes into an operational state of disabled until the LOS alarm state is cleared. The LOS alarm state is cleared when LOS defects are absent for 10 seconds +/- 0.5 second.

What is mscLpEE1LosAlarm?

This object indicates whether a LOS (Loss of Signal) alarm is currently active on this external E1 timing port, declared after LOS defects (all zeros observed for 150 ms) accumulate for about 2 seconds, and cleared after 10 seconds without LOS defects. While this alarm is active, the port's operational state is disabled. An admin seeing this alarm on(0) knows the external timing input has lost signal and can't currently be used as a clock reference until the condition clears.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.29.16.1.1
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB::mscLpEE1LosAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.29.16.1.1.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB::mscLpEE1LosAlarm.1

Start monitoring Nortel MsCarrier MscPassport switch (external E1 timing reference) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB::mscLpEE1LosAlarm OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport switch (external E1 timing reference) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1.12mscLpNortel-MsCarrier-MscPassport-LogicalProcessorMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.12.29mscLpEE1Nortel-MsCarrier-MscPassport-ExternalTimingE1MIB
1.3.6.1.4.1.562.36.2.1.12.29.16mscLpEE1OperTableNortel-MsCarrier-MscPassport-ExternalTimingE1MIB
1.3.6.1.4.1.562.36.2.1.12.29.16.1mscLpEE1OperEntryNortel-MsCarrier-MscPassport-ExternalTimingE1MIB
1.3.6.1.4.1.562.36.2.1.12.29.16.1.1mscLpEE1LosAlarmNortel-MsCarrier-MscPassport-ExternalTimingE1MIB