All MIBs › Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB › mscLpEDS1UsageState
mscLpEDS1UsageState
Module: Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB
OID (symbolic): Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB::mscLpEDS1UsageState
OID (numeric): 1.3.6.1.4.1.562.36.2.1.12.28.15.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no spare operating capacity for additional users at this time.
The OSI Status attributes, if supported by the component, may provide more details, qualifying the state of the component.
What is mscLpEDS1UsageState?
This object reports the OSI Usage State of the EDS1 component: idle if not currently in use, active if in use with spare capacity, or busy if in use with no spare capacity for additional users. Admins use it to gauge whether a timing component is actually serving as the active clock reference or sitting unused as a backup. For example, an EDS1 component reporting idle(0) is provisioned but not currently supplying timing to the system.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.28.15.1.3 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB::mscLpEDS1UsageState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.12.28.15.1.3.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB::mscLpEDS1UsageState.1
Start monitoring Nortel MsCarrier MscPassport (Passport) carrier switch, CPeD Control Processor (external DS1 timing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB::mscLpEDS1UsageState OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport (Passport) carrier switch, CPeD Control Processor (external DS1 timing) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.12 | mscLp | Nortel-MsCarrier-MscPassport-LogicalProcessorMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.12.28 | mscLpEDS1 | Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB |
| 1.3.6.1.4.1.562.36.2.1.12.28.15 | mscLpEDS1StateTable | Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB |
| 1.3.6.1.4.1.562.36.2.1.12.28.15.1 | mscLpEDS1StateEntry | Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB |
| 1.3.6.1.4.1.562.36.2.1.12.28.15.1.3 | mscLpEDS1UsageState | Nortel-MsCarrier-MscPassport-ExternalTimingDS1MIB |