All MIBs › Nortel-MsCarrier-MscPassport-DprsMcsEpMIB › mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw
mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw
Module: Nortel-MsCarrier-MscPassport-DprsMcsEpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1.5
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: This attribute specifies the maximum bandwidth that can be reserved by a Frame Relay PVC. The reverseCacType parameter specifies if this value is to be treated as an EIR or CIR value. If the reverseCacPolicy is set to monitored or the value of this attribute is set to noMaximum this check is not made. When this attribute is set to sameAsForward the reverseMaxPvcBw is the same as that specified by the forwardMaxPvcBw attribute.
VALUES (
155000001 = noMaximum
155000002 = sameAsForward
)
What is mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw?
Read-write maximum bandwidth (up to 155,000,000, 155000001 meaning noMaximum, or 155000002 meaning sameAsForward, the default) a single Frame Relay PVC can reserve in the reverse direction; not checked if reverseCacPolicy is monitored or set to noMaximum. Same purpose as the reverse SVC limit above, but for PVCs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1.5 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1.5.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1.5.1 i <value>
Start monitoring Nortel MsCarrier MscPassport WAN switch (DPRS MCS endpoint groups) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport WAN switch (DPRS MCS endpoint groups) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.2 | mscMcsMgrDprsMcsEpG | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3 | mscMcsMgrDprsMcsEpGEp | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5 | mscMcsMgrDprsMcsEpGEpCac | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2 | mscMcsMgrDprsMcsEpGEpCacCacd | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11 | mscMcsMgrDprsMcsEpGEpCacCacdRvrsTable | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1 | mscMcsMgrDprsMcsEpGEpCacCacdRvrsEntry | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.11.1.5 | mscMcsMgrDprsMcsEpGEpCacCacdReverseMaxPvcBw | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |