All MIBs › Nortel-MsCarrier-MscPassport-DprsMcsEpMIB › mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy
mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy
Module: Nortel-MsCarrier-MscPassport-DprsMcsEpMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy
OID (numeric): 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies the call admission policy which is to be used in the forward direction. When this attribute is set to enforced, a Frame Relay service connection fails call admission if there is insufficient effectiveBandwidth available in the forward direction, the forwardMaximumSvcBw is exceeded, or the forwardMaximumPvcBw is exceeded. Call admission failure causes the Frame Relay service connection to clear. When this attribute is set to monitored no Frame Relay service call will ever fail call admission.
What is mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy?
Read-write CAC policy for the forward direction: enforced(0) fails a connection's admission if insufficient effective bandwidth or the forward SVC/PVC maximum is exceeded, or monitored(1, default) never rejects a call. Set this to enforced to actually gate new Frame Relay connections by available forward bandwidth on this switched path.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1.1.1 i <value>
Start monitoring Nortel MsCarrier MscPassport WAN switch (DPRS MCS endpoint groups) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-DprsMcsEpMIB::mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport WAN switch (DPRS MCS endpoint groups) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.122 | mscMcsMgr | Nortel-MsCarrier-MscPassport-McsMgrMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.122.2 | mscMcsMgrDprsMcsEpG | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3 | mscMcsMgrDprsMcsEpGEp | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5 | mscMcsMgrDprsMcsEpGEpCac | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2 | mscMcsMgrDprsMcsEpGEpCacCacd | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10 | mscMcsMgrDprsMcsEpGEpCacCacdFrwdTable | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1 | mscMcsMgrDprsMcsEpGEpCacCacdFrwdEntry | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |
| 1.3.6.1.4.1.562.36.2.1.122.2.3.5.2.10.1.1 | mscMcsMgrDprsMcsEpGEpCacCacdForwardCacPolicy | Nortel-MsCarrier-MscPassport-DprsMcsEpMIB |