Nortel-MsCarrier-MscPassport-DcmeMIB :: mscDcmeProfileV17EncodedAsG711G726

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-MsCarrier-MscPassport-DcmeMIB › mscDcmeProfileV17EncodedAsG711G726

mscDcmeProfileV17EncodedAsG711G726

Module: Nortel-MsCarrier-MscPassport-DcmeMIB

OID (symbolic): Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileV17EncodedAsG711G726

OID (numeric): 1.3.6.1.4.1.562.36.2.1.129.2.11.1.19

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies how services using this Profile negotiate with V.17 fax machines. This attribute is not used unless the modemFaxEncoding, defined in this Profile, is faxRelayG711G726

If v17EncodedAsG711G726 is no, V.17 fax machines are instructed to use V.29 and V.29 fax traffic sent by fax machines is demodulated and encoded using fax relay.

If v17EncodedAsG711G726 is yes, V.17 fax machines are permitted to use V.17 and V.17 fax traffic sent by fax machines is encoded using G.711 or G.726. The actual encoding performed depends on the minModemFaxG711G726Rate and maxModemFaxG711G726Rate, available in this Profile.

What is mscDcmeProfileV17EncodedAsG711G726?

Controls how V.17 fax machines are handled when mscDcmeProfileModemFaxEncoding is faxRelayG711G726: no(0, the default) instructs V.17 machines to fall back to V.29 and demodulates via fax relay, yes(1) lets V.17 machines use V.17 and encodes that traffic as G.711/G.726 instead. Admins set this to yes if their fax machines need to negotiate the faster V.17 rate rather than being forced down to V.29.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.19
snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileV17EncodedAsG711G726

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.19.1
snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileV17EncodedAsG711G726.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.19.1 i <value>

Start monitoring Nortel MSC Passport mobile carrier switch (DCME voice compression trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileV17EncodedAsG711G726 OID value, configure state conditions and alerts, and monitor any Nortel MSC Passport mobile carrier switch (DCME voice compression trunk) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.36msCarrierNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2mscPassportNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.36.2.1mscComponentsNortel-MsCarrier-MscPassport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.36.2.1.129mscDcmeNortel-MsCarrier-MscPassport-DcmeMIB
1.3.6.1.4.1.562.36.2.1.129.2mscDcmeProfileNortel-MsCarrier-MscPassport-DcmeMIB
1.3.6.1.4.1.562.36.2.1.129.2.11mscDcmeProfileFrOpsTableNortel-MsCarrier-MscPassport-DcmeMIB
1.3.6.1.4.1.562.36.2.1.129.2.11.1mscDcmeProfileFrOpsEntryNortel-MsCarrier-MscPassport-DcmeMIB
1.3.6.1.4.1.562.36.2.1.129.2.11.1.19mscDcmeProfileV17EncodedAsG711G726Nortel-MsCarrier-MscPassport-DcmeMIB