All MIBs › Nortel-MsCarrier-MscPassport-DcmeMIB › mscDcmeProfileSilenceSuppression
mscDcmeProfileSilenceSuppression
Module: Nortel-MsCarrier-MscPassport-DcmeMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileSilenceSuppression
OID (numeric): 1.3.6.1.4.1.562.36.2.1.129.2.11.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies when silence suppression is performed. It applies to both voice and modem calls. If silenceSuppression is off, silence suppression is never performed. If silenceSuppression is on, silence suppression is always performed. If silenceSuppression is congested, silence suppression is performed only when the network is congested. If silenceSuppression is slow, silence suppression begins after 10 to 20 seconds without any detected speech or modem traffic. If silenceSuppression is slowAndCongested, both the slow and congested options are applied.
What is mscDcmeProfileSilenceSuppression?
Controls when silence suppression is applied to voice/modem traffic under this profile: off(0), on(1, the default, always suppress), congested(2, only under network congestion), slow(3, after 10-20s of no detected speech), or slowAndCongested(4, both conditions). Admins choose a less aggressive setting (e.g. congested) if silence suppression is causing clipped audio, or keep on(1) to maximize bandwidth savings.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.5 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileSilenceSuppression
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.5.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileSilenceSuppression.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.129.2.11.1.5.1 i <value>
Start monitoring Nortel MSC Passport mobile carrier switch (DCME voice compression trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-DcmeMIB::mscDcmeProfileSilenceSuppression OID value, configure state conditions and alerts, and monitor any Nortel MSC Passport mobile carrier switch (DCME voice compression trunk) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.129 | mscDcme | Nortel-MsCarrier-MscPassport-DcmeMIB |
| 1.3.6.1.4.1.562.36.2.1.129.2 | mscDcmeProfile | Nortel-MsCarrier-MscPassport-DcmeMIB |
| 1.3.6.1.4.1.562.36.2.1.129.2.11 | mscDcmeProfileFrOpsTable | Nortel-MsCarrier-MscPassport-DcmeMIB |
| 1.3.6.1.4.1.562.36.2.1.129.2.11.1 | mscDcmeProfileFrOpsEntry | Nortel-MsCarrier-MscPassport-DcmeMIB |
| 1.3.6.1.4.1.562.36.2.1.129.2.11.1.5 | mscDcmeProfileSilenceSuppression | Nortel-MsCarrier-MscPassport-DcmeMIB |