All MIBs › Nortel-MsCarrier-MscPassport-BusMIB › mscShelfTestAutomaticBusClockTest
mscShelfTestAutomaticBusClockTest
Module: Nortel-MsCarrier-MscPassport-BusMIB
OID (symbolic): Nortel-MsCarrier-MscPassport-BusMIB::mscShelfTestAutomaticBusClockTest
OID (numeric): 1.3.6.1.4.1.562.36.2.1.13.4.10.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies whether or not a bus clock source test is automatically executed after a clock source's LP state changes, and after failure or recovery of the active CP bus clock source. Since tests of an alternate bus clock source may cause a minor loss of traffic, the attribute is set to disabled by default. If set to enabled, a bus clock source test is automatically executed. If the status of the corresponding Shelf Bus clockSourceStatus is changed after the test, an alarm is issued if the status is one of the following: ok, failed, or unknown. If set to disabled, no bus clock source test is automatically executed. However, a test can be executed by the RUN command. If the status is changed after the test, an alarm is issued if the status is one of the following: ok, or failed.
What is mscShelfTestAutomaticBusClockTest?
Controls whether a bus clock-source test runs automatically whenever a clock source's LP state changes or the active CP clock source fails/recovers; disabled by default because testing the alternate source can cause a brief traffic hit, so an admin enables it deliberately when they want automatic alarms on clock-source changes.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.13.4.10.1.1 snmpwalk -v2c -c public <target> Nortel-MsCarrier-MscPassport-BusMIB::mscShelfTestAutomaticBusClockTest
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.36.2.1.13.4.10.1.1.1 snmpget -v2c -c public <target> Nortel-MsCarrier-MscPassport-BusMIB::mscShelfTestAutomaticBusClockTest.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.36.2.1.13.4.10.1.1.1 i <value>
Start monitoring Nortel MsCarrier MscPassport ATM switch (LANE Broadcast/Unknown Server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-MsCarrier-MscPassport-BusMIB::mscShelfTestAutomaticBusClockTest OID value, configure state conditions and alerts, and monitor any Nortel MsCarrier MscPassport ATM switch (LANE Broadcast/Unknown Server) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36 | msCarrier | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2 | mscPassport | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1 | mscComponents | Nortel-MsCarrier-MscPassport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.36.2.1.13 | mscShelf | Nortel-MsCarrier-MscPassport-BaseShelfMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.36.2.1.13.4 | mscShelfTest | Nortel-MsCarrier-MscPassport-BusMIB |
| 1.3.6.1.4.1.562.36.2.1.13.4.10 | mscShelfTestProvTable | Nortel-MsCarrier-MscPassport-BusMIB |
| 1.3.6.1.4.1.562.36.2.1.13.4.10.1 | mscShelfTestProvEntry | Nortel-MsCarrier-MscPassport-BusMIB |
| 1.3.6.1.4.1.562.36.2.1.13.4.10.1.1 | mscShelfTestAutomaticBusClockTest | Nortel-MsCarrier-MscPassport-BusMIB |