Nortel-Magellan-Passport-X25DteMIB :: x25DteProposeReverseCharging

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-X25DteMIB › x25DteProposeReverseCharging

x25DteProposeReverseCharging

Module: Nortel-Magellan-Passport-X25DteMIB

OID (symbolic): Nortel-Magellan-Passport-X25DteMIB::x25DteProposeReverseCharging

OID (numeric): 1.3.6.1.4.1.562.2.4.1.90.23.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies whether local/reverse charging is signalled in the call request packet.

What is x25DteProposeReverseCharging?

Sets whether outgoing call requests from this interface signal local or reverse charging by default, i.e., whether this end or the remote end is proposed to pay for the call.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.90.23.1.6
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-X25DteMIB::x25DteProposeReverseCharging

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.90.23.1.6.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-X25DteMIB::x25DteProposeReverseCharging.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.90.23.1.6.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> x25DteProposeReverseCharging.1

Start monitoring Nortel Magellan Passport WAN switch (X.25 DTE service) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-X25DteMIB::x25DteProposeReverseCharging OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport WAN switch (X.25 DTE service) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.90x25DteNortel-Magellan-Passport-X25DteMIB
1.3.6.1.4.1.562.2.4.1.90.23x25DteDcpTableNortel-Magellan-Passport-X25DteMIB
1.3.6.1.4.1.562.2.4.1.90.23.1x25DteDcpEntryNortel-Magellan-Passport-X25DteMIB
1.3.6.1.4.1.562.2.4.1.90.23.1.6x25DteProposeReverseChargingNortel-Magellan-Passport-X25DteMIB