Nortel-Magellan-Passport-VncsCallServerMIB :: vncsVpInsertedOutputDelay

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNortel-Magellan-Passport-VncsCallServerMIBvncsVpInsertedOutputDelay

vncsVpInsertedOutputDelay

Module: Nortel-Magellan-Passport-VncsCallServerMIB

OID (symbolic): Nortel-Magellan-Passport-VncsCallServerMIB::vncsVpInsertedOutputDelay

OID (numeric): 1.3.6.1.4.1.562.2.4.1.44.3.3.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies the amount of added output delay used to compensate for cross network delay variations. It applies to voice, modem and fax traffic. It is required to add output delay so that the statistical variation in the transit time of cells crossing the network does not cause gaps in speech. Backbone networks where high priority traffic consumes a high percentage of trunk bandwidth will require a higher insertedOutputDelay to compensate for the greater cell delay variation (CDV).

This attribute is ignored if this call runs on a 1pDS1V or 1pE1V card.

What is vncsVpInsertedOutputDelay?

This sets the amount of added output delay in milliseconds (one of n5 through n150, default n22) inserted to compensate for cross-network cell delay variation on calls using this VoiceProfile. Admins raise this on backbone networks where high-priority traffic consumes much of the trunk bandwidth, which increases delay variation and would otherwise cause audible gaps in speech; it is ignored on 1pDS1V/1pE1V cards.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.44.3.3.1.17
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-VncsCallServerMIB::vncsVpInsertedOutputDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.44.3.3.1.17.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-VncsCallServerMIB::vncsVpInsertedOutputDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.44.3.3.1.17.1 i <value>

Start monitoring Nortel Magellan Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-VncsCallServerMIB::vncsVpInsertedOutputDelay OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport switches from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.44vncsNortel-Magellan-Passport-VncsCallServerMIB
1.3.6.1.4.1.562.2.4.1.44.3vncsVpNortel-Magellan-Passport-VncsCallServerMIB
1.3.6.1.4.1.562.2.4.1.44.3.3vncsVpFrOpsTableNortel-Magellan-Passport-VncsCallServerMIB
1.3.6.1.4.1.562.2.4.1.44.3.3.1vncsVpFrOpsEntryNortel-Magellan-Passport-VncsCallServerMIB
1.3.6.1.4.1.562.2.4.1.44.3.3.1.17vncsVpInsertedOutputDelayNortel-Magellan-Passport-VncsCallServerMIB