Nortel-Magellan-Passport-VcTesterMIB :: vctDnaOutForceReverseCharge

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-VcTesterMIB › vctDnaOutForceReverseCharge

vctDnaOutForceReverseCharge

Module: Nortel-Magellan-Passport-VcTesterMIB

OID (symbolic): Nortel-Magellan-Passport-VcTesterMIB::vctDnaOutForceReverseCharge

OID (numeric): 1.3.6.1.4.1.562.2.4.1.5130.2.11.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies whether to force outgoing reverse charged calls. This attribute, if set to a value of yes forces reverse charging on all outgoing calls (from the DTE to the network) using this particular Dna unless the caller specifies a NUI in which case the call is charged to the NUI. If set to a value of no then reverse charging is not forced for outgoing calls. This attribute is ignored if the corresponding attribute, outCalls is set to a value of disallowed.This attribute must be semantically consistent with the corresponding attribute, outReverseChargeCalls.

What is vctDnaOutForceReverseCharge?

When set to yes, forces all outgoing calls from this Dna to be reverse-charged unless the caller specifies a NUI (in which case the NUI is billed instead); defaults to no. The MIB notes it must stay semantically consistent with vctDnaOutReverseCharge and is ignored if outgoing calls are disallowed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.2.11.1.4
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDnaOutForceReverseCharge

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.2.11.1.4.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDnaOutForceReverseCharge.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.5130.2.11.1.4.1 i <value>

Start monitoring Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-VcTesterMIB::vctDnaOutForceReverseCharge OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.5130vctNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.2vctDnaNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.2.11vctDnaOutgoingOptionsTableNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.2.11.1vctDnaOutgoingOptionsEntryNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.2.11.1.4vctDnaOutForceReverseChargeNortel-Magellan-Passport-VcTesterMIB