Type: HexString

Access: read-write

Description: This attribute contains the user data, if present. userData is a 0 to 16 length string which is appended to the call request packet that is presented to the called (destination) DTE.

User data can be a 0 to 128 byte string for fast select calls; otherwise it is 0 to 16 byte string.

Fast select calls are indicated as such using the X.25 ITU-T facility for 'Reverse Charging'.

The length of the user data attribute is not verified during service provisioning. If more than 16 bytes of user data is specified on a call without the fast select option, then the call is cleared with a clear cause of 'local procedure error', and a diagnostic code of 39 (as defined in the ITU-T X.25 Recommendation).

What is vctDcUserData?

The user-data string (0-16 bytes normally, up to 128 bytes for fast-select calls using the 'Reverse Charging' facility) appended to this direct call's call-request packet toward the destination DTE. The MIB warns that oversized user data on a non-fast-select call is not validated at provisioning time and instead causes the call to clear at connect time with a 'local procedure error' diagnostic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.8
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDcUserData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.8.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDcUserData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.8.1 s <value>

Start monitoring Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-VcTesterMIB::vctDcUserData OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.5130vctNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3vctDcNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10vctDcOptionsTableNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10.1vctDcOptionsEntryNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10.1.8vctDcUserDataNortel-Magellan-Passport-VcTesterMIB