Nortel-Magellan-Passport-VcTesterMIB :: vctDcSvcAutoCallRetry

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-VcTesterMIB › vctDcSvcAutoCallRetry

vctDcSvcAutoCallRetry

Module: Nortel-Magellan-Passport-VcTesterMIB

OID (symbolic): Nortel-Magellan-Passport-VcTesterMIB::vctDcSvcAutoCallRetry

OID (numeric): 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: svcAutoCallRetry is used only for switched calls, in which case the attribute type is set to switched. Otherwise, this attribute is ignored by the Vcs. This attribute, if set to yes for Svc, indicates that the Vc will continually try to establish the SVC rather than clearing the Vc after the first unsuccessful call attempt. Further, if the call fails while in data transfer phase, then the Vc will automatically attempt to reconnect. The call attempts are made by the Vc once per time provisioned in InterfaceOptions as callRetryTimer, repeatedly. If set to no for SVCs, then the Vc behaves in the standard mode, making a single call attempt.

What is vctDcSvcAutoCallRetry?

For switched calls only (vctDcType = switched), when set to yes causes the Vc to keep retrying to establish the SVC (and to auto-reconnect if it drops during data transfer) once per vctDcSvcAutoCallRetry interval, rather than making just a single attempt as when set to no (the default).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.7
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDcSvcAutoCallRetry

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.7.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-VcTesterMIB::vctDcSvcAutoCallRetry.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.5130.3.10.1.7.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> vctDcSvcAutoCallRetry.1

Start monitoring Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-VcTesterMIB::vctDcSvcAutoCallRetry OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport ATM switch (virtual-circuit test/loopback diagnostics) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.5130vctNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3vctDcNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10vctDcOptionsTableNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10.1vctDcOptionsEntryNortel-Magellan-Passport-VcTesterMIB
1.3.6.1.4.1.562.2.4.1.5130.3.10.1.7vctDcSvcAutoCallRetryNortel-Magellan-Passport-VcTesterMIB