Nortel-Magellan-Passport-UtpDpnTrunksMIB :: dpnGateUtpFramerFrameCrcType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-UtpDpnTrunksMIB › dpnGateUtpFramerFrameCrcType

dpnGateUtpFramerFrameCrcType

Module: Nortel-Magellan-Passport-UtpDpnTrunksMIB

OID (symbolic): Nortel-Magellan-Passport-UtpDpnTrunksMIB::dpnGateUtpFramerFrameCrcType

OID (numeric): 1.3.6.1.4.1.562.2.4.1.61.2.2.11.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute defines the type of CRC used.

The CRC value calculated is appended to the end of the frames transmitted to the link. The CRC value is removed from the end of frames received from the link and checked for correctness. NoCrc means that CRC is not used.

What is dpnGateUtpFramerFrameCrcType?

This read-write selector (crc16(0) default, crc32(1), or noCrc(2)) chooses the CRC algorithm appended to transmitted frames and checked on received frames for this Framer's link. Admins raise it to crc32 for stronger error detection on noisier or higher-speed links, or set noCrc where the frame integrity check is handled elsewhere.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.61.2.2.11.1.3
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-UtpDpnTrunksMIB::dpnGateUtpFramerFrameCrcType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.61.2.2.11.1.3.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-UtpDpnTrunksMIB::dpnGateUtpFramerFrameCrcType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.61.2.2.11.1.3.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dpnGateUtpFramerFrameCrcType.1

Start monitoring Nortel Magellan Passport WAN switch (UTP/copper DPN trunk) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-UtpDpnTrunksMIB::dpnGateUtpFramerFrameCrcType OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport WAN switch (UTP/copper DPN trunk) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1.61dpnGateNortel-Magellan-Passport-DpnTrunksMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.61.2dpnGateUtpNortel-Magellan-Passport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.2.2dpnGateUtpFramerNortel-Magellan-Passport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.2.2.11dpnGateUtpFramerLinkTableNortel-Magellan-Passport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.2.2.11.1dpnGateUtpFramerLinkEntryNortel-Magellan-Passport-UtpDpnTrunksMIB
1.3.6.1.4.1.562.2.4.1.61.2.2.11.1.3dpnGateUtpFramerFrameCrcTypeNortel-Magellan-Passport-UtpDpnTrunksMIB