Nortel-Magellan-Passport-DcmeMIB :: dcmeProfileV17EncodedAsG711G726

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-DcmeMIB › dcmeProfileV17EncodedAsG711G726

dcmeProfileV17EncodedAsG711G726

Module: Nortel-Magellan-Passport-DcmeMIB

OID (symbolic): Nortel-Magellan-Passport-DcmeMIB::dcmeProfileV17EncodedAsG711G726

OID (numeric): 1.3.6.1.4.1.562.2.4.1.129.2.11.1.19

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This attribute specifies how services using this Profile negotiate with V.17 fax machines. This attribute is not used unless the modemFaxEncoding, defined in this Profile, is faxRelayG711G726

If v17EncodedAsG711G726 is no, V.17 fax machines are instructed to use V.29 and V.29 fax traffic sent by fax machines is demodulated and encoded using fax relay.

If v17EncodedAsG711G726 is yes, V.17 fax machines are permitted to use V.17 and V.17 fax traffic sent by fax machines is encoded using G.711 or G.726. The actual encoding performed depends on the minModemFaxG711G726Rate and maxModemFaxG711G726Rate, available in this Profile.

What is dcmeProfileV17EncodedAsG711G726?

Specifies, only relevant when dcmeProfileModemFaxEncoding is faxRelayG711G726, how V.17 fax machines are handled under this profile: no(0) instructs them to fall back to V.29 and demodulates that traffic via fax relay, while yes(1) permits V.17 and encodes that traffic as G.711/G.726 at the rates set by the min/max modem-fax rate attributes. Admins enable yes only when the profile's min/max modem-fax G.711/G.726 rate settings can accommodate V.17's higher throughput.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.129.2.11.1.19
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dcmeProfileV17EncodedAsG711G726

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.129.2.11.1.19.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dcmeProfileV17EncodedAsG711G726.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.129.2.11.1.19.1 i <value>

Start monitoring Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-DcmeMIB::dcmeProfileV17EncodedAsG711G726 OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.129dcmeNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.129.2dcmeProfileNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.129.2.11dcmeProfileFrOpsTableNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.129.2.11.1dcmeProfileFrOpsEntryNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.129.2.11.1.19dcmeProfileV17EncodedAsG711G726Nortel-Magellan-Passport-DcmeMIB