All MIBs › Nortel-Magellan-Passport-DcmeMIB › dcmeProfilePathFailureAction
dcmeProfilePathFailureAction
Module: Nortel-Magellan-Passport-DcmeMIB
OID (symbolic): Nortel-Magellan-Passport-DcmeMIB::dcmeProfilePathFailureAction
OID (numeric): 1.3.6.1.4.1.562.2.4.1.129.2.10.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This attribute specifies whether the application can tolerate momentary interruption of a path while a new path is selected. If pathFailureAction is disconnectConnection, the application is informed as soon as possible about a failure by disconnection. If pathFailureAction is reRoutePath, the path may attempt an immediate reroute, provided the failure is a recoverable failure. If rerouting fails, the application is informed of the failure. If pathFailureAction is reRoutePath, the LCo may wait up to 30 seconds before informing the service of complete disconnection in order to allow both ends to attempt to reconnect. Note that if PLC components are different at both ends only the calling end is allowed to reconnect. All pathTypes respect this attribute. Also on a manualPath with both ends provisioned with independent paths (at least with respect to the failure) this option has the desired effect that the path is rerouted without complete disconnection at both ends.
What is dcmeProfilePathFailureAction?
Specifies whether an application using this profile can tolerate a momentary interruption while a path is rerouted: disconnectConnection(0) tells the application immediately on failure, while reRoutePath(1) attempts an immediate reroute (waiting up to 30 seconds before declaring full disconnection) if the failure is recoverable. Admins choose reRoutePath for traffic that should survive brief network blips rather than dropping the call outright.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.129.2.10.1.13 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dcmeProfilePathFailureAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.129.2.10.1.13.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dcmeProfilePathFailureAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.562.2.4.1.129.2.10.1.13.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dcmeProfilePathFailureAction.1
Start monitoring Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-DcmeMIB::dcmeProfilePathFailureAction OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.129 | dcme | Nortel-Magellan-Passport-DcmeMIB |
| 1.3.6.1.4.1.562.2.4.1.129.2 | dcmeProfile | Nortel-Magellan-Passport-DcmeMIB |
| 1.3.6.1.4.1.562.2.4.1.129.2.10 | dcmeProfileLCOpsTable | Nortel-Magellan-Passport-DcmeMIB |
| 1.3.6.1.4.1.562.2.4.1.129.2.10.1 | dcmeProfileLCOpsEntry | Nortel-Magellan-Passport-DcmeMIB |
| 1.3.6.1.4.1.562.2.4.1.129.2.10.1.13 | dcmeProfilePathFailureAction | Nortel-Magellan-Passport-DcmeMIB |