Nortel-Magellan-Passport-DcmeMIB :: dclVsLCoPathFailureAction

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › Nortel-Magellan-Passport-DcmeMIB › dclVsLCoPathFailureAction

dclVsLCoPathFailureAction

Module: Nortel-Magellan-Passport-DcmeMIB

OID (symbolic): Nortel-Magellan-Passport-DcmeMIB::dclVsLCoPathFailureAction

OID (numeric): 1.3.6.1.4.1.562.2.4.1.130.4.3.10.1.22

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This attribute displays whether the application is set to tolerate momentary interruption of a path while a new path is selected. If disconnectConnection is displayed, the application is informed as soon as possible about a failure by disconnection. If the attribute displays reRoutePath, the path may attempt an immediate reroute, provided the failure is a recoverable failure. If rerouting fails the application is informed of the failure. With this option set to reRoutePath the LCo may wait up to 30 seconds before informing the service of complete disconnection in order to allow both ends to attempt to reconnect. Note that if PLC components are different at both ends only the calling end is allowed to reconnect.

All pathTypes respect this attribute. Also on a manualPath with both ends provisioned with independent paths (at least with respect to the failure) this option will have the desired effect that the path is rerouted without complete disconnection at both ends

What is dclVsLCoPathFailureAction?

Reports whether this connection is set to tolerate a momentary interruption while a new path is selected: disconnectConnection(0) informs the application immediately on failure, while reRoutePath(1) attempts an immediate reroute (waiting up to 30 seconds before declaring full disconnection), inherited from the profile's dcmeProfilePathFailureAction. Admins check this to confirm the live connection is honoring the resilience behavior the profile was configured for.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.130.4.3.10.1.22
snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dclVsLCoPathFailureAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.130.4.3.10.1.22.1
snmpget -v2c -c public <target> Nortel-Magellan-Passport-DcmeMIB::dclVsLCoPathFailureAction.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dclVsLCoPathFailureAction.1

Start monitoring Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-DcmeMIB::dclVsLCoPathFailureAction OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport / Passport DPN multiservice switch (DCME voice compression) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.562nortelCPM-NORTEL-MIB
1.3.6.1.4.1.562.2magellanNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4passportNortel-Magellan-Passport-UsefulDefinitionsMIB
1.3.6.1.4.1.562.2.4.1componentsNortel-Magellan-Passport-UsefulDefinitionsMIB
Numeric OIDNameModule
1.3.6.1.4.1.562.2.4.1.130dclNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.130.4dclVsNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.130.4.3dclVsLCoNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.130.4.3.10dclVsLCoPathDataTableNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.130.4.3.10.1dclVsLCoPathDataEntryNortel-Magellan-Passport-DcmeMIB
1.3.6.1.4.1.562.2.4.1.130.4.3.10.1.22dclVsLCoPathFailureActionNortel-Magellan-Passport-DcmeMIB