All MIBs › Nortel-Magellan-Passport-ApsMIB › apsStandbyStatus
apsStandbyStatus
Module: Nortel-Magellan-Passport-ApsMIB
OID (symbolic): Nortel-Magellan-Passport-ApsMIB::apsStandbyStatus
OID (numeric): 1.3.6.1.4.1.562.2.4.1.134.12.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: If supported by the component, this attribute indicates the OSI Standby status of the component.
The value notSet indicates that either the attribute is not supported or that none of the status conditions described below are present. Note that this is a non-standard value, used because the original specification indicated this attribute was set-valued and thus, did not provide a value to indicate that none of the other three are applicable.
The value hotStandby indicates that the resource is not providing service but will be immediately able to take over the role of the resource to be backed up, without initialization activity, and containing the same information as the resource to be backed up.
The value coldStandby indicates the resource is a backup for another resource but will not be immediately able to take over the role of the backed up resource and will require some initialization activity.
The value providingService indicates that this component, as a backup resource, is currently backing up another resource.
What is apsStandbyStatus?
This read-only OID reports the APS component's OSI standby status: hotStandby (ready to take over instantly), coldStandby (needs initialization first), providingService (currently backing up another resource), or notSet, defaulting to notSet. It tells an admin the readiness level of a backup role this component may be playing.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.134.12.1.8 snmpwalk -v2c -c public <target> Nortel-Magellan-Passport-ApsMIB::apsStandbyStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.562.2.4.1.134.12.1.8.1 snmpget -v2c -c public <target> Nortel-Magellan-Passport-ApsMIB::apsStandbyStatus.1
Start monitoring Nortel Magellan Passport switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Nortel-Magellan-Passport-ApsMIB::apsStandbyStatus OID value, configure state conditions and alerts, and monitor any Nortel Magellan Passport switches from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.562 | nortel | CPM-NORTEL-MIB |
| 1.3.6.1.4.1.562.2 | magellan | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4 | passport | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| 1.3.6.1.4.1.562.2.4.1 | components | Nortel-Magellan-Passport-UsefulDefinitionsMIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.562.2.4.1.134 | aps | Nortel-Magellan-Passport-ApsMIB |
| 1.3.6.1.4.1.562.2.4.1.134.12 | apsStateTable | Nortel-Magellan-Passport-ApsMIB |
| 1.3.6.1.4.1.562.2.4.1.134.12.1 | apsStateEntry | Nortel-Magellan-Passport-ApsMIB |
| 1.3.6.1.4.1.562.2.4.1.134.12.1.8 | apsStandbyStatus | Nortel-Magellan-Passport-ApsMIB |