All MIBs › NSCRTV-FTTX-GPON-MIB › gponActiveAlarmAdditionalText
gponActiveAlarmAdditionalText
Module: NSCRTV-FTTX-GPON-MIB
OID (symbolic): NSCRTV-FTTX-GPON-MIB::gponActiveAlarmAdditionalText
OID (numeric): 1.3.6.1.4.1.17409.2.2.12.2.1.1.10
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: Additional info to the alarm, for further desciption of the alarm. The format of it shall be related to each kind alarm defined in alarm reference table
What is gponActiveAlarmAdditionalText?
This is free-form additional detail about the alarm in this active alarm table entry, formatted according to the vendor's alarm reference table for that alarm type. Admins read it for extra diagnostic context (such as a specific measured value) beyond the code and severity alone. For example, this could carry the measured optical power level that triggered a low-power alarm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.12.2.1.1.10 snmpwalk -v2c -c public <target> NSCRTV-FTTX-GPON-MIB::gponActiveAlarmAdditionalText
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.17409.2.2.12.2.1.1.10.1 snmpget -v2c -c public <target> NSCRTV-FTTX-GPON-MIB::gponActiveAlarmAdditionalText.1
Start monitoring GPON OLT/ONU devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NSCRTV-FTTX-GPON-MIB::gponActiveAlarmAdditionalText OID value, configure state conditions and alerts, and monitor any GPON OLT/ONU devices from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.17409 | nscrtvRoot | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2 | nscrtvEponEocTree | NSCRTV-EPONEOC-EPON-MIB |
| 1.3.6.1.4.1.17409.2.2 | alarmsIdent | NSCRTV-EPONEOC-EPON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.17409.2.2.12 | gponAlarmTree | NSCRTV-FTTX-GPON-MIB |
| 1.3.6.1.4.1.17409.2.2.12.2 | gponAlarmObjGroup | NSCRTV-FTTX-GPON-MIB |
| 1.3.6.1.4.1.17409.2.2.12.2.1 | gponActiveAlarmTable | NSCRTV-FTTX-GPON-MIB |
| 1.3.6.1.4.1.17409.2.2.12.2.1.1 | gponActiveAlarmEntry | NSCRTV-FTTX-GPON-MIB |
| 1.3.6.1.4.1.17409.2.2.12.2.1.1.10 | gponActiveAlarmAdditionalText | NSCRTV-FTTX-GPON-MIB |