NS-OPT-MIB :: cdx6500NetServCfgPortAndStnId

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NS-OPT-MIB › cdx6500NetServCfgPortAndStnId

cdx6500NetServCfgPortAndStnId

Module: NS-OPT-MIB

OID (symbolic): NS-OPT-MIB::cdx6500NetServCfgPortAndStnId

OID (numeric): 1.3.6.1.4.1.449.2.1.2.2.20.1.2

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: This parameter identifies the port and station that the Network Services Data Compression feature will be enabled on. The wild card (match anything) character is * and can also be part of the entry. The following are the only valid port types: X25- (Examples: X25-1(16) or X25-1*) FRA- (Examples: FRA-3S1 or FRA-3*) LCON- (Examples: LCON-1 or LCON-*) TCOP- (Examples: TCOP-1 or TCOP-*) TBOP- (Examples: TBOP-1 or TBOP-*). NOTE: The hyphen is required and there should be no leading spaces. The range is 0-31 alphanumeric characters, the default value is blank.

What is cdx6500NetServCfgPortAndStnId?

This read-only string (0-31 characters) identifies the port and station on which the Network Services Data Compression feature is enabled, using a hyphenated prefix like X25-, FRA-, LCON-, TCOP-, or TBOP- with an optional wildcard character (*) to match multiple stations, and defaults to blank. Admins configure it to target compression settings at a specific port/station or a group of them via the wildcard. For example, a value of FRA-3* enables the configured feature level for all stations on Frame Relay port 3.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.2.20.1.2
snmpwalk -v2c -c public <target> NS-OPT-MIB::cdx6500NetServCfgPortAndStnId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.2.20.1.2.1
snmpget -v2c -c public <target> NS-OPT-MIB::cdx6500NetServCfgPortAndStnId.1

Start monitoring Lucent/Cajun NS-series Ethernet switch (optical transceiver modules) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NS-OPT-MIB::cdx6500NetServCfgPortAndStnId OID value, configure state conditions and alerts, and monitor any Lucent/Cajun NS-series Ethernet switch (optical transceiver modules) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.2cdx6500CfgGeneralGroupBCST-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.2.20cdx6500NetServCfgTableNS-OPT-MIB
1.3.6.1.4.1.449.2.1.2.2.20.1cdx6500NetServCfgTableEntryNS-OPT-MIB
1.3.6.1.4.1.449.2.1.2.2.20.1.2cdx6500NetServCfgPortAndStnIdNS-OPT-MIB