NOTIFICATION-LOG-MIB :: nlmStatsGlobalNotificationsLogged

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NOTIFICATION-LOG-MIB › nlmStatsGlobalNotificationsLogged

nlmStatsGlobalNotificationsLogged

Module: NOTIFICATION-LOG-MIB

OID (symbolic): NOTIFICATION-LOG-MIB::nlmStatsGlobalNotificationsLogged

OID (numeric): 1.3.6.1.2.1.92.1.2.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of Notifications put into the nlmLogTable. This counts a Notification once for each log entry, so a Notification put into multiple logs is counted multiple times.

What is nlmStatsGlobalNotificationsLogged?

A running count of notifications written into the log table across all named logs, counting a notification once per log it lands in. An admin uses this as a coarse traffic gauge for how actively the device's event/trap subsystem is firing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.92.1.2.1
snmpwalk -v2c -c public <target> NOTIFICATION-LOG-MIB::nlmStatsGlobalNotificationsLogged

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.92.1.2.1.1
snmpget -v2c -c public <target> NOTIFICATION-LOG-MIB::nlmStatsGlobalNotificationsLogged.1

Start monitoring Vendor-neutral IETF standard (any SNMP-capable device, trap/inform logging) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NOTIFICATION-LOG-MIB::nlmStatsGlobalNotificationsLogged OID value, configure state conditions and alerts, and monitor any Vendor-neutral IETF standard (any SNMP-capable device, trap/inform logging) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing NOTIFICATION-LOG-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type nlmStatsGlobalNotificationsLogged into the Find box to locate it in the OID tree, then select it and click OK. The number of Notifications put into the nlmLogTable. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline (in notifications), since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.92notificationLogMIBNOTIFICATION-LOG-MIB
1.3.6.1.2.1.92.1notificationLogMIBObjectsNOTIFICATION-LOG-MIB
1.3.6.1.2.1.92.1.2nlmStatsNOTIFICATION-LOG-MIB
1.3.6.1.2.1.92.1.2.1nlmStatsGlobalNotificationsLoggedNOTIFICATION-LOG-MIB