nms510DiagEndToEndSelftest

Module: NMS510-MIB

OID (symbolic): NMS510-MIB::nms510DiagEndToEndSelftest

OID (numeric): 1.3.6.1.4.1.498.8.6.7.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: To initiate an End to End Selftest(Error Rate Test) SET this object and specifiy a blocksize. Both the remote (nms510) amd master (sc5520) units will go into Selftest. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are selftestOn(2) or selftestOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from both the remote (nms510) and master (sc5520) units. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test patternand cause errors. This test can also be terminated by seting the nms510DiagTestReset object.

What is nms510DiagEndToEndSelftest?

Sets a blocksize (1 to 50000 blocks) to start an end-to-end (error-rate) self-test spanning both the remote and master units, or reads back endToEndOn(2)/endToEndOff(1); results become available from both units once complete.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.8.6.7.1.4
snmpwalk -v2c -c public <target> NMS510-MIB::nms510DiagEndToEndSelftest

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.8.6.7.1.4.1
snmpget -v2c -c public <target> NMS510-MIB::nms510DiagEndToEndSelftest.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.8.6.7.1.4.1 i <value>

Start monitoring NMS Communications NMS510 device (DSU/CSU or similar telecom line unit) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NMS510-MIB::nms510DiagEndToEndSelftest OID value, configure state conditions and alerts, and monitor any NMS Communications NMS510 device (DSU/CSU or similar telecom line unit) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcDMA200-MIB
1.3.6.1.4.1.498.8dsuDDS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.8.6nms510NMS510-MIB
1.3.6.1.4.1.498.8.6.7nms510DiagExcTableNMS510-MIB
1.3.6.1.4.1.498.8.6.7.1nms510DiagExcEntryNMS510-MIB
1.3.6.1.4.1.498.8.6.7.1.4nms510DiagEndToEndSelftestNMS510-MIB