All MIBs › NIS-3500-2208PCE › rstpPerPortCfgAdminEdge
rstpPerPortCfgAdminEdge
Module: NIS-3500-2208PCE
OID (symbolic): NIS-3500-2208PCE::rstpPerPortCfgAdminEdge
OID (numeric): 1.3.6.1.4.1.25972.0.5.20.5.3.6.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Present in implementations that support the identification of edge ports. All ports directly connected to end stations cannot create bridging loops in the network and can thus directly transition to forwarding, skipping the listening and learning stages.
What is rstpPerPortCfgAdminEdge?
Marks this port as an edge port (true(1)) when it connects directly to an end station rather than another bridge, letting RSTP skip the listening/learning delay and go straight to forwarding since edge ports can't create loops.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.5.3.6.1.5 snmpwalk -v2c -c public <target> NIS-3500-2208PCE::rstpPerPortCfgAdminEdge
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.5.3.6.1.5.1 snmpget -v2c -c public <target> NIS-3500-2208PCE::rstpPerPortCfgAdminEdge.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.25972.0.5.20.5.3.6.1.5.1 i <value>
Start monitoring NIS 3500-2208PCE Industrial Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NIS-3500-2208PCE::rstpPerPortCfgAdminEdge OID value, configure state conditions and alerts, and monitor any NIS 3500-2208PCE Industrial Ethernet Switch from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25972 | company | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0 | switches | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5 | managedPoeSwitch | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20 | nis_3500_2208pce | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.5 | redundancy | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.5.3 | rstp | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.5.3.6 | rstpPerPortCfgTable | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.5.3.6.1 | rstpPerPortCfgEntry | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.5.3.6.1.5 | rstpPerPortCfgAdminEdge | NIS-3500-2208PCE |