NIS-3500-2208PCE :: eventRingTopologyChangeEvent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NIS-3500-2208PCE › eventRingTopologyChangeEvent

eventRingTopologyChangeEvent

Module: NIS-3500-2208PCE

OID (symbolic): NIS-3500-2208PCE::eventRingTopologyChangeEvent

OID (numeric): 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Parameter to indicate the event should be logged or should be sent as an Email alert. The value can't be log(1) or logandsmtp(3), if syslogStatus is disabled. The value can't be smtp(2) or logandsmtp(3), if eventEmailAlertStatus is disabled.

What is eventRingTopologyChangeEvent?

Sets how a redundant-ring topology-change event is reported: log(1), smtp(2), logandsmtp(3), or disabled(4); log/logandsmtp require syslogStatus enabled, and smtp/logandsmtp require eventEmailAlertStatus enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.5
snmpwalk -v2c -c public <target> NIS-3500-2208PCE::eventRingTopologyChangeEvent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.5.1
snmpget -v2c -c public <target> NIS-3500-2208PCE::eventRingTopologyChangeEvent.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.5.1 i <value>

Start monitoring NIS 3500-2208PCE Industrial Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NIS-3500-2208PCE::eventRingTopologyChangeEvent OID value, configure state conditions and alerts, and monitor any NIS 3500-2208PCE Industrial Ethernet Switch from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25972companyNIS-3500-2208PCE
1.3.6.1.4.1.25972.0switchesNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5managedPoeSwitchNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20nis_3500_2208pceNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20.11warningNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20.11.4eventSelectionNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20.11.4.1systemEventsTableNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20.11.4.1.1systemEventsEntryNIS-3500-2208PCE
1.3.6.1.4.1.25972.0.5.20.11.4.1.1.5eventRingTopologyChangeEventNIS-3500-2208PCE