All MIBs › NIS-3500-2208PCE › eventPowerStatusEvent
eventPowerStatusEvent
Module: NIS-3500-2208PCE
OID (symbolic): NIS-3500-2208PCE::eventPowerStatusEvent
OID (numeric): 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Parameter to indicate the event should be logged or should be sent as an Email alert. The value can't be log(1) or logandsmtp(3), if syslogStatus is disabled. The value can't be smtp(2) or logandsmtp(3), if eventEmailAlertStatus is disabled.
What is eventPowerStatusEvent?
Sets how a power-status-change event is reported: log(1), smtp(2), logandsmtp(3), or disabled(4); log/logandsmtp require syslogStatus enabled, and smtp/logandsmtp require eventEmailAlertStatus enabled.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.3 snmpwalk -v2c -c public <target> NIS-3500-2208PCE::eventPowerStatusEvent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.3.1 snmpget -v2c -c public <target> NIS-3500-2208PCE::eventPowerStatusEvent.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.3.1 i <value>
Start monitoring NIS 3500-2208PCE Industrial Ethernet Switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NIS-3500-2208PCE::eventPowerStatusEvent OID value, configure state conditions and alerts, and monitor any NIS 3500-2208PCE Industrial Ethernet Switch from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25972 | company | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0 | switches | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5 | managedPoeSwitch | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20 | nis_3500_2208pce | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.11 | warning | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.11.4 | eventSelection | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.11.4.1 | systemEventsTable | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.11.4.1.1 | systemEventsEntry | NIS-3500-2208PCE |
| 1.3.6.1.4.1.25972.0.5.20.11.4.1.1.3 | eventPowerStatusEvent | NIS-3500-2208PCE |