All MIBs › NEXANS-BM-MIB › portPoeAdminState
portPoeAdminState
Module: NEXANS-BM-MIB
OID (symbolic): NEXANS-BM-MIB::portPoeAdminState
OID (numeric): 1.3.6.1.4.1.266.20.3.1.1.21
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: If no POE adapter is installed this object is read-only and will always report notSupported(1). The possible values are: notSupported(1): No adapter installed or not supported for that port (i.e. uplink port). off(2): Adapter installed but inline power for that port is switched off. forcedOn(3): Adapter installed and inline power is asserted permanently. In the case of an IEEE802.3af adapter this setting will disable the IEEE802.3af automatic detection. autoOn(4): This setting is only supported if a IEEE802.3af adapter is installed. The adapter automatically detects if the connected device is IEEE802.3af compliant and will assert the power if possible. overloadFail(5): Adapter installed but inline power for that port is automatically switched off because of a overload condition at that port.
What is portPoeAdminState?
Controls inline power delivery on this port: off(2) disables it, forcedOn(3) asserts power permanently (bypassing 802.3af auto-detection), autoOn(4) lets an 802.3af adapter auto-detect a compliant device before powering it, and overloadFail(5) reports that power was automatically cut due to an overload; notSupported(1) means no PoE adapter is installed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.21 snmpwalk -v2c -c public <target> NEXANS-BM-MIB::portPoeAdminState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.21.1 snmpget -v2c -c public <target> NEXANS-BM-MIB::portPoeAdminState.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.266.20.3.1.1.21.1 i <value>
Start monitoring Nexans Advanced Networking Solutions switching equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NEXANS-BM-MIB::portPoeAdminState OID value, configure state conditions and alerts, and monitor any Nexans Advanced Networking Solutions switching equipment from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.266 | nexansANS | NEXANS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.266.20 | bmSwitchMIB | NEXANS-BM-MIB |
| 1.3.6.1.4.1.266.20.3 | bmSwitchPort | NEXANS-BM-MIB |
| 1.3.6.1.4.1.266.20.3.1 | bmSwitchPortTable | NEXANS-BM-MIB |
| 1.3.6.1.4.1.266.20.3.1.1 | bmSwitchPortEntry | NEXANS-BM-MIB |
| 1.3.6.1.4.1.266.20.3.1.1.21 | portPoeAdminState | NEXANS-BM-MIB |