NEXANS-BM-MIB :: portBandwidthLimitTxd

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › NEXANS-BM-MIB › portBandwidthLimitTxd

portBandwidthLimitTxd

Module: NEXANS-BM-MIB

OID (symbolic): NEXANS-BM-MIB::portBandwidthLimitTxd

OID (numeric): 1.3.6.1.4.1.266.20.3.1.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The bandwidth limiter for transmitted packets. If set to disable(2) the limiter will be disabled.

What is portBandwidthLimitTxd?

Caps how much outbound (transmitted) traffic this port is allowed to send, from 128 kbit/s up to 256 Mbit/s, or disable(2) to remove the limit entirely.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.16
snmpwalk -v2c -c public <target> NEXANS-BM-MIB::portBandwidthLimitTxd

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.16.1
snmpget -v2c -c public <target> NEXANS-BM-MIB::portBandwidthLimitTxd.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.266.20.3.1.1.16.1 i <value>

Start monitoring Nexans Advanced Networking Solutions switching equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NEXANS-BM-MIB::portBandwidthLimitTxd OID value, configure state conditions and alerts, and monitor any Nexans Advanced Networking Solutions switching equipment from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.266nexansANSNEXANS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.266.20bmSwitchMIBNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3bmSwitchPortNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1bmSwitchPortTableNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1.1bmSwitchPortEntryNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1.1.16portBandwidthLimitTxdNEXANS-BM-MIB