NEXANS-BM-MIB :: portAcApSetup

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › NEXANS-BM-MIB › portAcApSetup

portAcApSetup

Module: NEXANS-BM-MIB

OID (symbolic): NEXANS-BM-MIB::portAcApSetup

OID (numeric): 1.3.6.1.4.1.266.20.3.1.1.28

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: If portAcApSetup is enabled, the switch will perform Autocrossover and Autopolarity for this port. This function should only be enabled if portSpeedDuplexSetup ist set to autoneg.

What is portAcApSetup?

Enables Auto-Crossover and Auto-Polarity detection on this port, intended for use only when portSpeedDuplexSetup is set to autoneg.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.28
snmpwalk -v2c -c public <target> NEXANS-BM-MIB::portAcApSetup

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.266.20.3.1.1.28.1
snmpget -v2c -c public <target> NEXANS-BM-MIB::portAcApSetup.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.266.20.3.1.1.28.1 i <value>

Start monitoring Nexans Advanced Networking Solutions switching equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NEXANS-BM-MIB::portAcApSetup OID value, configure state conditions and alerts, and monitor any Nexans Advanced Networking Solutions switching equipment from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.266nexansANSNEXANS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.266.20bmSwitchMIBNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3bmSwitchPortNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1bmSwitchPortTableNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1.1bmSwitchPortEntryNEXANS-BM-MIB
1.3.6.1.4.1.266.20.3.1.1.28portAcApSetupNEXANS-BM-MIB