NETONIX-SWITCH-MIB :: dcdcInputCurrent

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NETONIX-SWITCH-MIB › dcdcInputCurrent

dcdcInputCurrent

Module: NETONIX-SWITCH-MIB

OID (symbolic): NETONIX-SWITCH-MIB::dcdcInputCurrent

OID (numeric): 1.3.6.1.4.1.46242.7

Node type: OBJECT-TYPE

Type: CurrentTC

Access: read-only

Description: DCDC Input Current in amps

What is dcdcInputCurrent?

This read-only value reports how many amps of current are flowing into the switch's DC-DC power converter, expressed with one decimal place via the CurrentTC convention. Monitoring it helps admins catch abnormal power draw or a failing supply before it causes a brownout, since a sudden spike often signals a hardware fault or an overloaded PoE load. For example, a value that normally reads around 21.3 amps jumping to 45.0 amps would prompt an admin to investigate a short or an overloaded converter.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.46242.7
snmpwalk -v2c -c public <target> NETONIX-SWITCH-MIB::dcdcInputCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.46242.7.1
snmpget -v2c -c public <target> NETONIX-SWITCH-MIB::dcdcInputCurrent.1

Start monitoring Netonix managed switch (WISP-oriented) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NETONIX-SWITCH-MIB::dcdcInputCurrent OID value, configure state conditions and alerts, and monitor any Netonix managed switch (WISP-oriented) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.46242netonixSwitchNETONIX-SWITCH-MIB
1.3.6.1.4.1.46242.7dcdcInputCurrentNETONIX-SWITCH-MIB