NETONIX-SWITCH-MIB :: dcdcEfficiency

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NETONIX-SWITCH-MIB › dcdcEfficiency

dcdcEfficiency

Module: NETONIX-SWITCH-MIB

OID (symbolic): NETONIX-SWITCH-MIB::dcdcEfficiency

OID (numeric): 1.3.6.1.4.1.46242.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: DCDC power supply efficiency, percentage

What is dcdcEfficiency?

This read-only value reports, as a percentage, how efficiently the switch's DC-DC power converter turns input power into usable output power. A drop in this percentage over time can signal aging or failing power-supply components, since a healthy converter should stay close to its rated efficiency. For example, if dcdcEfficiency normally reads 92 but drops to 70, an admin should suspect the converter is degrading and wasting more power as heat.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.46242.8
snmpwalk -v2c -c public <target> NETONIX-SWITCH-MIB::dcdcEfficiency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.46242.8.1
snmpget -v2c -c public <target> NETONIX-SWITCH-MIB::dcdcEfficiency.1

Start monitoring Netonix managed switch (WISP-oriented) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NETONIX-SWITCH-MIB::dcdcEfficiency OID value, configure state conditions and alerts, and monitor any Netonix managed switch (WISP-oriented) from a single console.

How to Use in IPNetwork Monitor

Select a Netonix managed switch (WISP-oriented) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dcdcEfficiency into the Find box to locate it in the OID tree, then select it and click OK. It reports dCDC power supply efficiency, percentage. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the value drifts significantly from its normal baseline, since an unexpected change often points to a real underlying issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.46242netonixSwitchNETONIX-SWITCH-MIB
1.3.6.1.4.1.46242.8dcdcEfficiencyNETONIX-SWITCH-MIB