NETGEAR-POWER-ETHERNET-MIB :: agentPethOutputVolts

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NETGEAR-POWER-ETHERNET-MIB › agentPethOutputVolts

agentPethOutputVolts

Module: NETGEAR-POWER-ETHERNET-MIB

OID (symbolic): NETGEAR-POWER-ETHERNET-MIB::agentPethOutputVolts

OID (numeric): 1.3.6.1.4.1.4526.10.15.1.1.1.4

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: The voltage this port is supplying to an attached device measured in millivolts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4526.10.15.1.1.1.4
snmpwalk -v2c -c public <target> NETGEAR-POWER-ETHERNET-MIB::agentPethOutputVolts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4526.10.15.1.1.1.4.1
snmpget -v2c -c public <target> NETGEAR-POWER-ETHERNET-MIB::agentPethOutputVolts.1

Start monitoring Netgear managed PoE switch (Power Sourcing Equipment hardware detail) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NETGEAR-POWER-ETHERNET-MIB::agentPethOutputVolts OID value, configure state conditions and alerts, and monitor any Netgear managed PoE switch (Power Sourcing Equipment hardware detail) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4526netgearFSM726S-MIB
1.3.6.1.4.1.4526.10ng7000managedswitchNetgear-MIB
1.3.6.1.4.1.4526.10.15fastPathpowerEthernetMIBBROADCOM-POWER-ETHERNET-MIB
1.3.6.1.4.1.4526.10.15.1agentPethObjectsBROADCOM-POWER-ETHERNET-MIB
1.3.6.1.4.1.4526.10.15.1.1agentPethPsePortTableBROADCOM-POWER-ETHERNET-MIB
1.3.6.1.4.1.4526.10.15.1.1.1agentPethPsePortEntryBROADCOM-POWER-ETHERNET-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4526.10.15.1.1.1.4agentPethOutputVoltsNETGEAR-POWER-ETHERNET-MIB