NBS-ODSYS-MIB :: nbsOdsysPsVOutActual

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-ODSYS-MIBnbsOdsysPsVOutActual

nbsOdsysPsVOutActual

Module: NBS-ODSYS-MIB

OID (symbolic): NBS-ODSYS-MIB::nbsOdsysPsVOutActual

OID (numeric): 1.3.6.1.4.1.629.228.5.2.1.60

Node type: OBJECT-TYPE

Type: NbsTcMilliVolt

Access: read-only

Description: Indicates the output voltage reading, in millivolts

What is nbsOdsysPsVOutActual?

This OID reports the power supply's measured output voltage, in millivolts, the voltage it delivers to the chassis. An admin monitors it alongside nbsOdsysPsVOutLevel to catch a failing supply, since the nbsOdsysTrapPsVOutLevelBad notification fires when it drifts out of range.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.60
snmpwalk -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsVOutActual

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.60.1
snmpget -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsVOutActual.1

Start monitoring MRV Opti-Driver optical chassis (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-ODSYS-MIB::nbsOdsysPsVOutActual OID value, configure state conditions and alerts, and monitor any MRV Opti-Driver optical chassis (hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.228nbsOdsysMibNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5nbsOdsysPsGrpNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2nbsOdsysPsTableNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2.1nbsOdsysPsEntryNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2.1.60nbsOdsysPsVOutActualNBS-ODSYS-MIB