All MIBs › NBS-ODSYS-MIB › nbsOdsysPsVOutActual
nbsOdsysPsVOutActual
Module: NBS-ODSYS-MIB
OID (symbolic): NBS-ODSYS-MIB::nbsOdsysPsVOutActual
OID (numeric): 1.3.6.1.4.1.629.228.5.2.1.60
Node type: OBJECT-TYPE
Type: NbsTcMilliVolt
Access: read-only
Description: Indicates the output voltage reading, in millivolts
What is nbsOdsysPsVOutActual?
This OID reports the power supply's measured output voltage, in millivolts, the voltage it delivers to the chassis. An admin monitors it alongside nbsOdsysPsVOutLevel to catch a failing supply, since the nbsOdsysTrapPsVOutLevelBad notification fires when it drifts out of range.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.60 snmpwalk -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsVOutActual
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.60.1 snmpget -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsVOutActual.1
Start monitoring MRV Opti-Driver optical chassis (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-ODSYS-MIB::nbsOdsysPsVOutActual OID value, configure state conditions and alerts, and monitor any MRV Opti-Driver optical chassis (hardware inventory) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | GSWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.228 | nbsOdsysMib | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.5 | nbsOdsysPsGrp | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.5.2 | nbsOdsysPsTable | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.5.2.1 | nbsOdsysPsEntry | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.5.2.1.60 | nbsOdsysPsVOutActual | NBS-ODSYS-MIB |