NBS-ODSYS-MIB :: nbsOdsysPsChasIndex

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsNBS-ODSYS-MIBnbsOdsysPsChasIndex

nbsOdsysPsChasIndex

Module: NBS-ODSYS-MIB

OID (symbolic): NBS-ODSYS-MIB::nbsOdsysPsChasIndex

OID (numeric): 1.3.6.1.4.1.629.228.5.2.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The nbsCmmcChassisIndex of this power supply's chassis

What is nbsOdsysPsChasIndex?

This OID is the chassis index (nbsCmmcChassisIndex) of the chassis that hosts this power supply, the first of two index values identifying a row in the power supply table. An admin uses it to locate which chassis a power supply status reading belongs to.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.1
snmpwalk -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsChasIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.629.228.5.2.1.1.1
snmpget -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysPsChasIndex.1

Start monitoring MRV Opti-Driver optical chassis (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-ODSYS-MIB::nbsOdsysPsChasIndex OID value, configure state conditions and alerts, and monitor any MRV Opti-Driver optical chassis (hardware inventory) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.629nbaseGSWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.629.228nbsOdsysMibNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5nbsOdsysPsGrpNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2nbsOdsysPsTableNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2.1nbsOdsysPsEntryNBS-ODSYS-MIB
1.3.6.1.4.1.629.228.5.2.1.1nbsOdsysPsChasIndexNBS-ODSYS-MIB