All MIBs › NBS-ODSYS-MIB › nbsOdsysFtThermLevel
nbsOdsysFtThermLevel
Module: NBS-ODSYS-MIB
OID (symbolic): NBS-ODSYS-MIB::nbsOdsysFtThermLevel
OID (numeric): 1.3.6.1.4.1.629.228.4.1.1.40
Node type: OBJECT-TYPE
Type: NbsTcStatusLevel
Access: read-only
Description: Indicates level of current temperature reading with respect to the FtTherm threshold objects below
What is nbsOdsysFtThermLevel?
This OID indicates how the fan tray's current temperature (nbsOdsysFtThermActual) compares to its configured warning and error thresholds. An admin watches this value because it drives the nbsOdsysTrapFtThermLevelBad and nbsOdsysTrapFtThermLevelOk notifications for the tray.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.629.228.4.1.1.40 snmpwalk -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysFtThermLevel
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.629.228.4.1.1.40.1 snmpget -v2c -c public <target> NBS-ODSYS-MIB::nbsOdsysFtThermLevel.1
Start monitoring MRV Opti-Driver optical chassis (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the NBS-ODSYS-MIB::nbsOdsysFtThermLevel OID value, configure state conditions and alerts, and monitor any MRV Opti-Driver optical chassis (hardware inventory) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.629 | nbase | GSWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.629.228 | nbsOdsysMib | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.4 | nbsOdsysFtGrp | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.4.1 | nbsOdsysFtTable | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.4.1.1 | nbsOdsysFtEntry | NBS-ODSYS-MIB |
| 1.3.6.1.4.1.629.228.4.1.1.40 | nbsOdsysFtThermLevel | NBS-ODSYS-MIB |